Oil analysis
Manual — Lubrication · chapter 9 of 12
The Oil analysis tab holds the laboratory reports, per asset. The report is typed in and the PDF goes as an attachment.
Figure 14. The Oil analysis tab.
- 1The Oil analysis tab.
- 2The filters by verdict: Normal, Caution and Critical, with the count.
- 3New report.
- 4A report: sampling date, asset, point and lubricant, verdict, laboratory and the main figures. Click to open it.
Recording a report
Section titled “Recording a report”- Click New report and choose the asset type and the asset.
- If you wish, indicate the sampling point and the lubricant in use.
- Enter the sampling date and the laboratory’s verdict.
- Fill in the figures of the report and the elements in ppm.
- Click Save and attach the PDF of the report.

Figure 15. An oil analysis report.
- 1The laboratory’s verdict. Tick Oil changed at this sampling when that is the case.
- 2The elements in ppm: wear, contamination and additives.
- 3The attached report (PDF or image).
- 4The asset trend.
| Field | What it is |
|---|---|
| Viscosity 40 °C / 100 °C | In cSt. |
| Water | In ppm. |
| TAN / TBN | Acid number and base number, in mg KOH/g. |
| Particles ISO 4406 | The cleanliness code, in the format 18/16/13. |
| Oil hours / Equipment hours | The usage on the sampling date. |
| Laboratory diagnosis and Recommendation | The laboratory’s text. |
| Ticket | The number of the ticket in which the sample was taken or that handled the report. |
The trend
Section titled “The trend”When you open a report, the Asset trend panel shows, for each figure, the series of all the asset’s samples, the latest value and the change from the previous sample.
Was this page helpful?
Thanks for the feedback!
Got it — we will improve this page.