Updating, pairing again, moving and removing

Manual — Data collectors · chapter 8 of 10

The collector’s day-to-day does not call for maintenance. This chapter covers the exceptions: new version of the program, change of computer, cutting off access and removal.

I want to… Do Where
update the program nothing: ATG updates it —
pair a collector again (access revoked, token lost) Generate another token and run the installer checking Parear de novo (Pair again) H2O and customer computer
change the collector computer Generate another token on the same collector and install on the new computer H2O and new computer
stop the collector for a while uncheck Collector active Settings tab
cut off the access of an installation Revoke access Settings tab, Pairing card
do away with the collector Delete collector and uninstall the program H2O and customer computer

The one who publishes a new version and orders the update is ATG only. You do not need to go to the customer and there is no update command on the screen. When there is a version newer than the installed one, H2O just informs, in amber, below the version — in the Version column of the list and in the data of the Pairing card: Version N available. The update is done by ATG.

When ATG sends the update, the collector downloads the version, checks the file, replaces the program and restarts by itself, in seconds; if the new version does not come up, it goes back to the previous one. On the Commands tab, the request appears as Update version, with ATG in the Requested by column. The stored readings and the pairing are kept.

Pair again when the status is Access revoked, when the tray icon turns red with O H2O recusou o token deste coletor (H2O refused the token of this collector), or when the token was generated and lost before the installation.

  1. In H2O, open the collector, Settings tab, and click Generate another token. H2O confirms New token generated. The previous one is no longer valid. Copy the token.
  2. On the customer computer, run the installer as administrator and advance to the Ligação com o H2O (Connection to H2O) screen.
  3. The screen informs that the computer is already paired. Check Parear de novo com um token novo (troca o token deste coletor) (Pair again with a new token (replaces the token of this collector)).
  4. Type the token in the Token de pareamento (Pairing token) field and click Avançar. Finish the installation.

The collector record — linked assets, points, rules — stays in H2O. Changing computers is just pairing the new installation on the same collector:

  1. Check, on the Health tab, that the Local cache is Empty — the readings kept on the old computer do not pass to the new one.
  2. In H2O, on the Settings tab of the collector, click Generate another token.
  3. Install the program on the new computer with that token (chapter 4).
  4. Check in the list: the collector goes back to Running, now with the name of the new computer.
  5. Uninstall the program from the old computer (below).

On the Settings tab, uncheck Collector active and click Save. The status becomes Inactive: H2O stops accepting the collector calls, shows no alert in the bell and does not open a ticket for a collector with no contact. Nothing is erased.

To come back, check Collector active and save. If the collector does not go back to Running within a few minutes, restart the service through the tray icon; if the icon says that H2O refused the token, pair again.

Revoke access, in the Pairing card, cuts off the current installation: use it when the computer was stolen, discarded or left the customer’s control. The button only appears on a paired collector.

  1. On the Settings tab, Pairing card, click Revoke access.
  2. The button becomes Confirm: the collector stops sending. Click again.
  3. H2O confirms: Access revoked. To resume, generate another token and pair again.
After revoking How it stands
collector status Access revoked
the installation on the computer H2O refuses it at the next call; the icon turns red
token generated and not yet used is no longer valid
linked assets, points and readings already stored stay as they are
alerts in the bell and no-contact ticket are not generated for a revoked collector
to come back Generate another token and pair again

On the Settings tab, click Delete collector; the button becomes Confirm deletion. H2O confirms Collector deleted. and goes back to the list. The button requires the Trash box of the Data collectors right (chapter 2).

On deleting How it stands
the installation on the computer is cut off, as in Revoke access
the collector disappears from the list; the screen has no way to bring it back
the readings already stored remain in the history of the asset measurements
the asset measurements become free to receive a point from another collector
the program on the customer computer remains installed, unable to send: uninstall it
  1. In Windows, open Settings › Apps, find H2O Link Coletor and click Uninstall.
  2. Confirm the question Remover o H2O Link Coletor deste computador? O serviço de coleta para de enviar medições ao H2O. (Remove H2O Link Coletor from this computer? The collection service stops sending measurements to H2O.)
  3. The uninstaller asks whether it should also remove the collector data in C:\ProgramData\H2O Coletor. Answer No if you are going to reinstall on this computer; Yes if the computer is going out of use.

The uninstallation removes the service, the tray icon and the automatic startup. The data folder keeps the pairing, the configuration and the readings not yet sent — hence the question.