Frequently asked questions and messages
Manual — Data collectors · chapter 10 of 10
The most common questions come first. The table at the end translates the messages that may appear on the collector screens.Installation and network
Section titled “Installation and network”- Does the customer IT team need to open any inbound port? No. The collector only makes outbound connections, over HTTPS (port 443), to
api.prod.atg.com.br. No port is opened on the computer or on the customer network (chapter 2). - What is the H2O address I enter in the installer? None. The installer already knows where H2O is: leave Produção (o H2O do cliente) (Production (the customer’s H2O)) selected and enter only the token. The customer IT team, to allow the outbound traffic, uses
api.prod.atg.com.br. - Windows warned that it protected the PC. Is it safe to continue? The installer does not yet have a digital signature recognised by Windows, hence the warning. Continue through More info › Run anyway — provided the file was downloaded through the H2O link or delivered by ATG.
- Do I need to be logged in to H2O on the customer computer? No. The installer link opens without login and the token can be read from another screen, from a phone or from a note.
- Can I install on a virtual machine? Yes, provided it stays on all the time and can reach the equipment network.
- I lost the token. What now? There is no way to see it again: H2O does not keep the readable token. Click Generate another token on the Settings tab. The previous one is no longer valid.
- The token expired before I installed. It is valid for 24 hours. Generate another one.
- Can I use the same token on two computers? No. The token is single use and each collector accepts one installation at a time. For two computers, create two collectors.
- Can the collector be installed on Linux or Mac? The installer the screen offers is for Windows. For other cases, talk to ATG.
Assets, points and measurements
Section titled “Assets, points and measurements”- Do I need to register the asset first? Yes. The collector does not create assets: it links assets that already exist in the collector site or in the selected subsites.
- The asset does not appear in the list for linking. The list brings only the assets of the chosen Asset type that are in the collector site or in a selected subsite: No assets of this type in the collector site and subsites. Check the asset site and the Subsites this collector can read.
- Do I need to register the measurements before creating the points? By hand, yes: the point asks for an Asset measurement that already exists. Through Map with AI, by model, by copy and by the BACnet discovery, no: whatever measurement is missing is created along with it.
- Can I have two points storing in the same measurement? No. Each measurement gets readings from a single point. H2O refuses and says which point of which collector already feeds the measurement.
- Can I link the same asset in two collectors? Yes — the screen warns with Also linked in: —, provided each collector feeds different measurements.
- I changed a point. Do I need to go to the customer? No. The change goes down by itself in about a minute. To speed it up, Reload configuration on the Commands tab.
- Does the manual reading through the app still work? It does, as always. The collector readings stay in the measurement history, on the web, and are not downloaded by the apps.
- Where do I see the chart? In the asset record, Metering tab — the same as for manual readings. The Points tab of the collector shows only the last value of each point.
- How often does the collector read? At the interval of each point, the Read every (s) field — 60 seconds by default, from 1 second to 1 day.
- Does “Read now” store the reading? No. It only shows the value on the screen, to check the map.
- How many points does Map with AI create at once? Up to 40 per application. A model holds up to 500 points.
- Is the AI always right? No. With the MIB file, the addresses come from the file itself; with a spreadsheet or PDF, check the addresses; without a file, it is a draft without addresses. In all cases, use Read now before applying.
Operation, alerts and tickets
Section titled “Operation, alerts and tickets”- The customer internet went down. Did I lose the readings? No. The collector keeps the readings on the computer and sends everything, in order, when the internet returns. The history is complete, with the time each reading was taken.
- How long does H2O take to notice that the collector went down? After 3 minutes without a report the status becomes No contact and the alert goes into the bell. The ticket, if turned on, opens after the minutes chosen in the record (15 by default), with up to 5 minutes of tolerance.
- Does the collector ticket close by itself when it comes back? No. A follow-up goes in announcing the return and how long it was out; whoever handles it decides to close.
- The reading left the range and no ticket was opened. Check whether the asset metric has a range and Open ticket on anomaly checked — a measurement created by the AI, by a model or by the discovery is born without it — and the Late readings rule of the collector.
- Will it open one ticket per minute while the value is out of range? No. It is one ticket per ongoing anomaly; H2O only records again when the situation changes (became critical, went back into range).
- Who sees the collector alerts in the bell? Those who have Read in Data collectors and can see the collector site.
- How do I update the program? You do not: ATG publishes the version and sends the update. The screen only informs Version N available. The update is done by ATG.
- I changed the customer computer. Do I need to redo the points? No. Generate another token on the same collector and install on the new computer: the assets and the points remain (chapter 8).
- How long is the collector log kept? 24 months.
- Can the DIN rail device be used already? The H2O Link Collector device option already appears in the record, but the pairing through the app arrives with the device. For now, use the Software collector.
Messages
Section titled “Messages”| Message | Where | Why | What to do |
|---|---|---|---|
| This feature is not available in this environment yet: the database update (…) has not been applied. | list and collector page | the environment has not received the module yet | ask ATG support |
| The equipment and points tabs…, Commands…, The model library… is (are) not available in this environment yet / This option is not available in this environment yet / Outage history is not available in this environment yet | collector tabs, ticket card, Health tab | a database update is missing for that part | ask ATG support; the rest of the module works |
| Could not load. / Could not save. | any screen | network or server failure, or missing right | reload the page; check the Edit right (chapter 2) |
| Collector not found. | collector page | the collector was deleted or belongs to a site outside your scope | go back to the list; ask for access to the site |
| Enter the collector name. / Choose the collector site. | New collector | required field empty | fill it in |
| A collector with this name already exists in this site. | saving the collector | repeated name in the same site | use another name |
| There are linked assets in: … Unlink those assets before removing the subsite from the collector. | saving the Settings | you unchecked a subsite that still has a linked asset | unlink the assets of that subsite or leave it checked |
| This collector is inactive. Activate it before generating the token. | Generate another token | Collector active unchecked | check Collector active, save and generate the token |
| Could not copy. Select the token and copy it. / Could not copy. Select the link and copy it. | Copy token, Copy link | the browser blocked the clipboard | select the text and copy with the keyboard |
| This asset does not belong to the site or subsites of this collector. | Link asset | the asset is in another site | select the subsite in the collector or move the asset |
| Enter the equipment address. | saving the link | the main field of the protocol (IP, serial port, base URL) is empty | fill it in |
| Invalid value in field “…”. | link or point | number out of range (port, id, register, number of registers) or unknown option (parity, table, method) | correct the field mentioned |
| The protocol can only be changed while the asset has no points. | Edit the link | the link already has points | delete the points, or unlink and link again |
| Link an asset before creating points. | New point | the collector has no linked asset | Equipment tab › Link asset |
| Enter the point name, measurement and address. | saving the point | required field empty | fill it in |
| Enter the point address on the equipment. | saving the point; Read now | the main field of the address (register, instance, OID, topic) is empty | fill it in |
| The selected measurement does not belong to this asset. | saving the point | the measurement was deleted or deactivated, or belongs to another asset | choose another measurement |
| Measurement “…” is already fed by point “…” of collector “…”. … | saving the point; applying a proposal | the measurement already has a point | choose another measurement or delete that point |
| Measurement “…” was chosen for two points in this request. … | applying an AI proposal or discovery objects | two selected points point to the same measurement | change the measurement of one of them |
| AI service unavailable right now. Try again in a moment. | Ask the AI for a proposal | the AI service did not answer | try again |
| The AI did not return a usable map. Try again or send another file. | Ask the AI for a proposal | the AI answer could not be used | try again; send a clearer file |
| Could not read the file. Send the MIB, a spreadsheet, a text file or the PDF of the manufacturer map. | Ask the AI for a proposal | unrecognised format or damaged file | send it in another format |
| The collector must be paired and active to receive commands. | commands, Read now, Discover on the network | collector not paired, revoked or inactive | pair or activate the collector |
| The collector did not answer in time. | Read now | a minute without an answer | see the collector status; try again |
| Too many points to read at once. | Read now in Map with AI | more than 50 points selected | select fewer points at a time |
| Enter the network as 192.168.10.0/24 (from /24 to /32). | Discover on the network | range in another format or larger than 256 addresses | correct the range; scan in stretches |
| Invalid port: use a number from 1 to 65535. | Discover on the network | port out of range | correct it |
| A model with this name already exists for this protocol. | Save as model, Import model | repeated name | use another name |
| The protocol is not the same as the linked asset. | Apply model, Copy points | model or source asset with another protocol | choose one of the same protocol |
| There are no points to store in the model. / Enter the model name. | Save as model | asset without points; empty name | create the points; fill in the name |
| The file is not a collector model. | Import model | the file was not generated by Export | import a file exported from the library |